Flow cytometry automation: when walk-away plate runs are worth setting up

Table of Contents

In a busy flow lab, most of your day goes to the work around the cytometer. You load plates, add reagents on schedule, clean between runs, keep sixty samples on the same timing, and stay late when a run is long. Automation takes those steps off the operator. For the right workload, it turns a day of hands-on work into a run you set up and leave.

Whether it is worth setting up depends on the shape of your work. Count the plates you run each week, how often the same protocol repeats, and how many people need consistent results from one instrument. Merkel Technologies supplies Stratedigm's automation suite in Israel alongside the flow cytometry analyzers it offers, and the suite scales from single plates and Eppendorf tubes to hundreds of plates.

What flow cytometry automation takes off your team

A plate loader is the core. Stratedigm's A600 autosampler draws from the plate with six injection probes and an all-ceramic pump. It has zero dead volume and carryover below 1% on control beads, and its rapid screening mode reads a 96-well plate in under 15 minutes. Options add injection volumes from 5 to 400 µL, programmable mixing, probe sterilisation between samples, a barcode reader and temperature control from 8 to 40 °C.

Around the loader sit the steps that usually need a person. Liquid handling can add up to 24 different reagents to any well, and a bulk reagent module feeds the plates. The A800 incubator holds temperature and shakes the plates. The A710 plate hotel stores up to 240 plates in sequential racks and moves them between the modules.

Where automation pays back first

High-throughput screening is the obvious case: thousands of samples across many plates in one experiment. Multi-plate work comes next, where you define an experiment once and it runs across plates without re-entering the setup. Then come routine assays that repeat every week. Core facilities gain consistent handling across many users and projects.

Measure the gain in hours of hands-on time returned to the people in your lab. A run you start in the afternoon and leave overnight gives back the evening someone would otherwise spend at the cytometer.

Timing that a person cannot hold

Many assays depend on timing: a stain incubated for a fixed period, a stimulation stopped at a set minute, sixty wells read at the same stage. Done by hand across several plates, those times drift. Stratedigm's Multi-Plate Conductor schedules the steps across plates and runs them in parallel where they do not interfere. For example, it can incubate one plate while liquid handling proceeds on the next. It also adjusts the schedule from each plate's status as the run goes.

What to check before trusting an automated run

Start with carryover, which decides how many of one well's cells turn up in the next, and dead volume, which decides how much sample you lose. Ask for the figures on control beads and on your own sample type.

Then check plate formats: the hotel handles 24-, 96- and 384-well plates, lidded or unlidded. Finally, decide who will write the protocols. In Stratedigm's Visual Protocol Designer, an optional part of its CellCapTure software, you build them by drag and drop, with no programming. It covers pipetting, mixing, incubation, centrifugation and automated compensation.

Before you switch your lab to automated runs, run your current protocol both ways on the same samples. The comparison shows whether the automated version needs adjusting. It also gives you the evidence to show your users that their results have not moved.

Starting with a plate loader

Automation does not have to arrive all at once. Stratedigm calls the A600 its gateway to flow cytometry automation. A plate loader with liquid handling on a compact cytometer is the first step. The plate hotel, incubators and scheduling can join it as your runs grow to many plates, which keeps the first purchase in proportion to the work you have now.

If you are still choosing the cytometer itself, our guide to choosing a flow cytometry analyzer covers the instrument questions, and spectral panel design covers the panel.

Testing automation on your own plates

Your workload decides the configuration, so test your own plates and protocol in a proof of concept before you commit to a configuration. Our team in Israel installs the suite, trains your operators and services it. Contact us to plan the test. No cost and no obligation for a first consultation.